How to Reduce Energy Consumption in Pneumatic Conveying for Cement Plants
The Hidden Motor: How to Reduce Energy Consumption in Pneumatic Conveying

Walk past a screw pump in almost any cement plant and you'll hear it working hard. A big motor is spinning a screw, forcing cement into a pressurized line, all day, every day.
Now ask a simple question: what is that motor actually conveying? The answer is nothing. The air does the conveying. The screw motor exists only to push material into the line, and it draws serious power doing it.
That makes the screw drive one of the easiest places to reduce energy consumption in pneumatic conveying. And with cement producers under growing pressure to cut power and carbon, it's a target worth going after. The IEA says cement needs to cut CO2 emissions about 4% a year to stay on a net-zero path, and pneumatic conveying takes about 40% of the power used by a plant's low-pressure air applications.
This article explains where the energy goes in a screw pump system, and three proven ways to take the screw motor out of the equation.
Where the Energy Goes in a Screw Pump System
Screw pumps, often called FK pumps, have fed cement conveying lines for decades. They're flexible and familiar. But they pay two energy bills every hour they run.
Bill #1: the conveying air. A blower or compressor supplies the air that carries material down the line. Every pneumatic system pays this one.
Bill #2: the screw drive. A large electric motor turns a tapered, high-speed screw that compresses material into a plug and forces it into the pressurized line. This motor does no conveying at all. It only gets material in the door.
That second bill is the one most plants never question.
The screw drive also costs money in less obvious ways:
Wear drives power up. As flights and barrel liners wear, the pump needs more power to make the same rate, and blowback air increases.
Rebuilds are frequent and expensive. Screws, liners and seals all wear in abrasive cement service.
Overload trips cost throughput. A screw pump running near its motor limit trips when the feed rate or conveying pressure spikes.
Three Ways to Eliminate the Screw Motor
The fastest way to cut the screw drive's energy bill is to stop paying it. Each of the options below feeds the conveying line without a large motor turning a screw, so the power that motor used to draw simply comes off the bill.
1. High-Pressure Rotary Valve (HPXL Extreme Rotary Valve)
A high-pressure rotary valve meters material into the line with a slowly turning rotor instead of a high-speed screw. It needs only a small gearmotor to turn, a fraction of what a screw pump demands.
Delta Ducon's HPXL Extreme Rotary Valve is rated to 35 psig and 500°F, and handles up to 65 TPH of cement (at 90 lb/ft³). It's built from chrome-iron alloy rated over 550 Brinell, so it stands up to abrasive cement and kiln dust, and it can be rebuilt rather than replaced.
Best for: dilute phase lines up to roughly 50 to 60 TPH, where you want a simple, reliable replacement.
2. ROTOfeed-K
The ROTOfeed-K feeds material from a pressurized vessel through a heavy-duty rotor into the conveying line. There's no screw to turn, and the drive is sized only to meter material, not to force it against line pressure.
Delta Ducon has documented over 40% savings in annual energy costs with the ROTOfeed-K versus screw pumps of similar capacity.
Best for: continuous, accurately metered feed at higher pressures, including blended cement and process injection.
3. Dense Phase Conveying
Dense phase removes the rotating feeder entirely. Material is loaded into a pressure vessel, and compressed air pushes it down the line in slow-moving slugs. With no screw and no rotor, there's no feeder motor drawing power at all.
Dense phase also uses far less air per ton than dilute phase, which lowers the conveying-air bill too. And because the material moves slowly, abrasive wear on pipe and elbows drops sharply.
Best for: high tonnages, long distances and the most abrasive materials. Delta Ducon supplies dense phase systems through its partnership with Clyde Pneumatic Conveying, including the Denseveyor®, D-Pump® and MD-Pump®.
Screw Pump vs. the Alternatives at a Glance
Screw pump (FK) | HPXL rotary valve | ROTOfeed-K | Dense phase | |
Large screw drive motor | Yes | No | No | No |
Feeder drive | Large motor, high speed | Small gearmotor, slow rotor | Small variable-speed drive | None |
Conveying mode | Dilute | Dilute | Dilute to semi-dense | Dense |
Air per ton conveyed | High | High | Moderate | Low |
Abrasive wear | High (screw, liners) | Low (550+ Brinell, rebuildable) | Low (replaceable rotor tips) | Lowest (slow velocity) |
Typical fit | Legacy installs | Up to ~50–60 TPH | Metered, continuous feed | High TPH, long distance |
Ratings vary by application; every system is sized to your material and route.
More Ways to Cut Conveying Power
Removing the screw motor is the biggest single win. A few other steps add to the savings:
Right-size the air. More air isn't more capacity. Excess velocity wastes power and speeds up wear, and pushing pressure higher often causes blockages instead of curing them.
Fix air leaks. Leaking fittings, worn seals and blowback through a worn feeder all waste compressed air you've already paid to make.
Keep wear under control. Worn rotors and elbows leak air and lose capacity. Abrasion-resistant components like PERMA/flo pipe and elbows hold system performance steady for longer.
Simplify the route. Fewer bends and shorter runs mean lower pressure drop and less air for the same tonnage.
Choosing the Right Screw Pump Replacement
The best option depends on what your line needs to do. Start with these questions:
How many tons per hour? Up to roughly 50 to 60 TPH, a high-pressure rotary valve is often the simplest swap. Above that, look at ROTOfeed-K or dense phase.
How far, and how many bends? Long, demanding routes favor dense phase.
How abrasive is the material? All three handle abrasives, but dense phase gives the biggest drop in pipeline wear.
Do you need accurate metering? For blending or precise feed rates, the ROTOfeed-K's variable-speed drive is a natural fit.
How much downtime can you take? Some upgrades drop into the existing screw pump footprint; others need a new system design.
The common thread: every option removes the large screw motor, so every option starts saving energy from day one.
Frequently Asked Questions
Why do screw pumps use so much energy? On top of the conveying air, a screw pump needs a large motor to turn a high-speed screw that forces material into the pressurized line. That motor does no conveying, so it's pure overhead.
What's the best way to reduce energy consumption in pneumatic conveying? Start by eliminating the screw drive motor with a high-pressure rotary valve, a ROTOfeed-K or a dense phase system. Then right-size the conveying air and fix leaks.
Is a rotary valve more energy efficient than a screw pump? Yes, in most cement applications. A high-pressure rotary valve turns slowly with a small gearmotor instead of a large screw drive.
How much energy can I save by replacing a screw pump? It depends on the application, but Delta Ducon has documented over 40% savings in annual energy costs with the ROTOfeed-K versus screw pumps of similar capacity.
Does dense phase conveying use less energy? Dense phase has no rotating feeder motor and uses much less air per ton than dilute phase, which often lowers total conveying power, especially over long distances.
Stop Paying for the Screw
If your plant is still running screw pumps, part of your conveying power bill is going to a motor that never moves a single ton down the line. Removing it is one of the most direct ways to reduce energy consumption in pneumatic conveying, and to show real progress on your plant's carbon goals.
Delta Ducon has been engineering pneumatic conveying for cement for over 100 years, with high-pressure rotary valves, ROTOfeed-K and dense phase systems built in the U.S. for abrasive service. Tell us about your screw pump, and we'll show you what replacing it could save.
Call Delta Ducon at (800) 238-2974 or email info@deltaducon.com